L&G EM Speed log 4020Mk2 

Full compatibility with most Walker flush fitting, fixed or retractable speed log sensors and hull fittings. Digital Speed and Distance Run displays by red LED dimmable indicators. Multipoint speed calibration as speeds from up to 60 knots. Removable keypad “calibrator”. Built-in Speed Simulator. NMEA 0183/RS422 and 200 ppnm outputs to other ship systems. Repeater indicators to DIN144 standard (optional). Simple to install, operate and service. EM Speed Log technology drawn from over 30...
Information
  • Full compatibility with most Walker flush fitting, fixed or retractable speed log sensors and hull fittings.
  • Digital Speed and Distance Run displays by red LED dimmable indicators.
  • Multipoint speed calibration as speeds from up to 60 knots.
  • Removable keypad “calibrator”.
  • Built-in Speed Simulator.
  • NMEA 0183/RS422 and 200 ppnm outputs to other ship systems.
  • Repeater indicators to DIN144 standard (optional).
  • Simple to install, operate and service.
  • EM Speed Log technology drawn from over 30 years’ experience.
Specifications

A low frequency AC Electromagnetic sensor induces an electrical voltage in the sea water. This voltage is detected by two electrodes in the sensor face and converted to a speed reading in the Master unit. Distance run is derived by accurately integrating the speed value with respect to time.

Speed Range -20 to 60.0 kts

Resolution 0.1 kt

System accuracy +/- 2%

Calibration accuracy, 0.1 kt 0 to 10 kt,

+/- 1% above 10 kt

Distance

Trip Distance 0 to 99,999.9 nm with front panel reset.

Total distance 99,999.9 nm

Accuracy – integrated from speed to 0.02%

Displays Red LED, dimmable to off

Lamp test built in.

Controls Power On/Off, Simulator On/Off, Set Simulator

Speed, Distance Reset, Lamp Test, Illumination

Up/Down

Interfacing 2 x Outputs – NMEA 0183\RS422.

Sentences VLW and VHW

2 x Outputs – 200 ppnm.

Isolated relay contacts of distance travelled.

To switch max power 10W

max current 0.5A

max voltage 200 vDC

Products
Document & Download

Download Brochure here!

Đăng ký nhận bản tin
X

A PHP Error was encountered

Severity: Warning

Message: ini_set(): open_basedir restriction in effect. File() is not within the allowed path(s): (/home/inmatech/:/tmp/:/var/tmp/:/opt/alt/php71/usr/share/pear/:/dev/urandom:/usr/local/php56/lib/:/usr/local/php71/lib/:/usr/local/php56/lib/:/usr/local/php70/lib/:/usr/local/php73/lib/:/usr/local/lib/php/)

Filename: public_html/index.php

Line Number: 236