DanelecConnect

DanelecConnect Intelligent and cost e­ cient ship-2-shore data solutions 6-STEP SHIP-2-SHORE DATA SOLUTION PROCESS 1. COLLECT An Internet-of-Things (IoT) infrastructure collects data onboard via a Vessel Remote Server module (mini VDR) 2. SELECT Data is pre-processed on board and can be managed and customized from shore 3. TRANSFER Less than 1MB data per day is transferred to shore at fixed intervals or if triggered by special events 4. STORE Data is stored on a Danelec server (Danelec Cloud...
Information

DanelecConnect

DanelecConnect Intelligent and cost e­ cient ship-2-shore data solutions

6-STEP SHIP-2-SHORE DATA SOLUTION PROCESS

1. COLLECT
An Internet-of-Things (IoT) infrastructure collects data onboard via a Vessel Remote Server module (mini VDR)

2. SELECT
Data is pre-processed on board and can be managed and customized from shore

3. TRANSFER
Less than 1MB data per day is transferred to shore at fixed intervals or if triggered by special events

4. STORE
Data is stored on a Danelec server (Danelec Cloud solution)

5. EXTRACT
The ship manager assigns data access to authorized users

6. ANALYZE 
User creates customized views in DanelecConnect dashboard or may use data in Remote Management application for:

·      Monitoring and performance optimization

·      Safety and Bridge Operating Quality Assurance (BOQA)

·      Remote maintenance (Pre-APT, alarm diagnostics and configuration)

Connectivity modules

Cost e­ cient loT infrastructure Danelec’s ship-2-shore data solutions are powered by our connectivity Hardware modules. Developed using our decades of expertise with VDR (Voyage Data Recorder) technology and supported by our worldwide service network for installation and maintenance, these hardware modules provide the basic building blocks of a cost e­ cient internet-of-things (IoT) infrastructure onboard vessels. Remote Data Interface modules pick up analog, digital or serial sensor data throughout the ship for on-board data collection, while the Vessel Remote Server module connects to the vessel’s existing network/communication infrastructure for data transfer to shore. Danelec connectivity modules work with existing Danelec VDR installations or any other VDR make and model, and can even be applied on vessels without a VDR on board.

Danelec-connectivity-modules

Remote Management Tool

Secure VDR access from shore

Danelec’s Remote Management Tool enables instant access to the vessel’s VDR (Voyage Data Recorder) from a PC on shore for transfer and replay of recorded VDR data in case of an incident or emergency situation. For the mandatory VDR Annual Performance Tests (APT) access can be provided to a VDR service technician in order to perform diagnostics of the system or to run a pre-APT test while the vessel is at sea, speeding up the actual APT when the ship arrives in port. If extended access to the VDR is enabled by the vessel’s crew, even remote confi guration of the system is possible from shore, without physically attending the vessel.

 

DanelecConnect dashboard

Data for e­ffcient asset management

Irrespective of whether the vessel is equipped with a VDR (Voyage Data Recorder) or not, the DanelecConnect dashboard provides a gateway to all vessel-related data measurements from shore. Forget about the hassles of noon-reports. The ship operations team on shore can request data from specifi c sensors or set up a schedule of regularly recorded serial, analog and digital data downloads from each connected sensor. The data is pre-processed and compressed, allowing for the use of narrowband satellite channels and resulting in less than 1 MB of data transfer per day. Data can be displayed in customizable dashboards for monitoring of various vessel parameters from shore (such as position, speed, RPM, etc.), as well as trends within the data over time. The collected data can also be applied in advanced analytics solutions such as vessel performance and fuel optimization applications.

DanelecConnect 01

Specifications
Products
Relative Products
Document & Download

- Brochure

Đăng ký nhận bản tin
X

A PHP Error was encountered

Severity: Warning

Message: ini_set(): open_basedir restriction in effect. File() is not within the allowed path(s): (/home/inmatech/:/tmp/:/var/tmp/:/opt/alt/php71/usr/share/pear/:/dev/urandom:/usr/local/php56/lib/:/usr/local/php71/lib/:/usr/local/php56/lib/:/usr/local/php70/lib/:/usr/local/php73/lib/:/usr/local/lib/php/)

Filename: public_html/index.php

Line Number: 236